Energy Storage & Solar Technical Resources


Expert insights on energy storage systems, solar containers, battery cabinets, photovoltaic technology, telecom solar, and road system solutions for South African markets

We provide professional energy storage and solar solutions to customers across South Africa, including Gauteng, Western Cape, KwaZulu-Natal, Eastern Cape, Free State, Mpumalanga, Northern Cape, Limpopo, and North West provinces, as well as neighboring countries including Botswana, Namibia, Zimbabwe, Mozambique, Eswatini, and Lesotho.
Our expertise in energy storage systems, storage containers, battery cabinets, photovoltaic solutions, telecom solar systems, and road system solar ensures reliable performance for various applications. Whether you need industrial energy storage, commercial solar systems, telecom power solutions, or road lighting systems, BUHLE POWER has the engineering expertise to deliver optimal results with competitive pricing and reliable technical support.

TIDA-01606 reference design | TI

TIDA-01606 11-kW, bidirectional three-phase three-level (T-type) inverter and PFC reference design Design files Overview Design files & products Start development Technical

Control Design of Single-Phase T-Type Inverters for PV

May 1, 2023 · The typical topology of a T-type converter used in PV applications is shown in Fig. 1, which consists of IGBT switches and a boost reactor. With the pulse width modu-lation

10kW 3-phase 3-level T-type inverter reference design for solar

This proven reference design outlines how to implement a three-level, three-phase DC/AC T-inverter stage based on SiC. The higher switching frequency of 50KHz reduces the size of the

25kW Grid-Tied Bi-directional T-Type Inverter with High

Jun 13, 2024 · In the past decade, solar installations have experienced substantial expansion, primarily driven by their myriad benefits, such as economical operation, scalability, flexible

Full SiC Three-Level T-Type Quasi-Z Source

Apr 25, 2025 · As a relatively recent advanced inverter topology, the three-level T-type quasi-impedance source inverter (3L T-Type qZSI) offers the

Capacitor ripple reduction in T-type multilevel inverter

Aug 15, 2023 · Multilevel inverters for their benefits are being explored for low-power applications. In this work, recently introduced 9-level T-Type switched-capacitor multilevel inverters are

T-Type vs NPC: which topology scales better for solar ESS?

Sep 3, 2025 · Boost your solar ESS performance. Compare T-Type and NPC inverter topologies to see which scales best for efficiency, cost, and power density.

Choosing the Right 3-Level Inverter: T-Type vs. T-NPC

Jun 19, 2025 · # T-type vs. T-NPC: A Technical Deep Dive into 3-Level Inverter Topologies In the pursuit of higher power density and efficiency for systems like solar inverters, uninterruptible

Full SiC Three-Level T-Type Quasi-Z Source Inverter as Grid

Apr 25, 2025 · As a relatively recent advanced inverter topology, the three-level T-type quasi-impedance source inverter (3L T-Type qZSI) offers the improved harmonic distortion and lower

11-kW, Bidirectional Three-Phase Three-Level (T-type)

Feb 20, 2025 · 11-kW, Bidirectional Three-Phase Three-Level (T-type) Inverter and PFC Reference Design Description This reference design provides an overview on how to

T-Type vs NPC: which topology scales better

Sep 3, 2025 · Boost your solar ESS performance. Compare T-Type and NPC inverter topologies to see which scales best for efficiency, cost, and

Three-Phase T-Type Inverter

Feb 13, 2024 · 1 Overview This demonstration presents a three-phase T-type inverter for grid-tie applications that deploys Wolf-speed SiC MOSFETs. Fig. 1 shows the electrical circuit of the T

Technical FAQs 4

What is a T-type solar inverter?

Peak efficiency at partial load is critical. This is the defining use case for T-type, making it ideal for solar string inverters, which spend most of their operational life at 20-60% of their rated power. The superior conduction loss performance directly translates to more harvested energy.

What is a T-type inverter rated at 22 kVA?

The demo model shows an example of a T-type inverter rated at 22 kVA that converts an 800 V DC-bus into a three-phase 60 Hz, 480 V (line-line, rms) distribution for industrial applications. All 12 devices are configured to demonstrate the thermal loss performance of different Wolfspeed SiC MOSFETs.

What is a T-type 3-level inverter?

The next step up from a standard two-level inverter is a T-type three-level inverter. This type is implemented by inserting two back-to-back switching devices between the switch node and the neutral point of the DC link created by the bulk input capacitors.

What are the topologies of a 3 level inverter?

Within the 3-level inverter family, two prominent topologies stand out: the T-type and the T-type Neutral Point Clamped (T-NPC), also commonly known as Active NPC (ANPC). While both aim to achieve similar outcomes, their internal structures, loss characteristics, and operational trade-offs are significantly different.

Related Technical Topics

BUHLE POWER Engineering Support Team

Engineering Support for Energy Storage & Solar Projects

Our certified engineering team provides comprehensive technical support for all installed energy storage systems and solar installations. From initial system design and engineering to ongoing maintenance, optimization, and performance monitoring, BUHLE POWER ensures your energy storage and solar solutions operate at peak efficiency throughout their lifecycle, with 24/7 monitoring available for critical telecommunications and industrial applications.

Contact Engineering Support

Stay Updated on Energy Storage & Solar Technology

Subscribe to our technical newsletter for the latest innovations in energy storage systems, photovoltaic technology, telecom solar solutions, road system solar, and industry developments across Southern Africa. Stay informed about cutting-edge solutions in renewable energy technology.